Skip to main content

Menu

OHAUS Laboratory Centrifuges: Compare Models for Your 2027 Restock

November 19, 2026

Share to Social Media

ohaus-laboratory-centrifuges-restock-2027-wiltronics

OHAUS Laboratory Centrifuges: Compare Models for Your 2027 Restock

The end-of-year laboratory stocktake is an opportunity to replace unsuitable equipment, expand sample capacity and replenish the accessories that keep your prep room working.

When comparing laboratory centrifuges, start with four requirements: tube size, samples per run, required centrifugal force and the rotor included with the instrument. These determine whether a compact mini centrifuge, a larger-volume system or a specialist microcentrifuge belongs on your purchasing list.

At Wiltronics, our OHAUS range provides several options for school science departments and laboratories preparing for 2027. The comparison below brings the instruments and purchasing considerations together.


Compare OHAUS centrifuges

 

Model Main purchasing consideration Rotor and tube configuration
OHAUS FC5306 Mini Centrifuge Compact equipment for routine small-volume spin-downs Includes an eight-place 1.5/2 mL rotor and a four-place PCR strip rotor
OHAUS FC2706 Multi Centrifuge Flexibility to select a rotor around your sample requirements Optional rotors listed separately; configurations cover 10–100 mL formats
OHAUS FC2706 with R11 Rotor A defined instrument-and-rotor package for larger tubes Includes the OH30694811 six-place 50 mL angle rotor
OHAUS FC2516 Micro Centrifuge Specialist microtube preparation requiring higher centrifugal force Multiple rotor options; confirm the configuration and supplied accessories

Rotor capacity is specific to the installed rotor. An instrument’s maximum listed capacity does not mean every package includes the rotor needed to achieve it.


OHAUS FC5306: compact equipment for small-volume preparation

 

https://www.wiltronics.com.au/product/17016/frontier-mini-centrifuge/

The OHAUS Frontier FC5306 Mini Centrifuge is a practical option to assess when replacing a basic spin-down instrument. Its supplied rotors accommodate eight 1.5/2 mL tubes or four eight-tube PCR strips, with adapters allowing smaller tubes to be used in the microtube rotor.

The FC5306 offers one-touch operation, a compact footprint and a listed maximum relative centrifugal force of 2,000 × g. Consider it where routine small-volume preparation is the priority, and check that its capabilities match the department’s established methods.


OHAUS FC2706: configure the instrument around your tubes

 

ohaus-fc2706-frontier-2000-multi-centrifuge

The OHAUS FC2706 Frontier 2000 Multi Centrifuge provides a choice of separately listed rotors, allowing the setup to be selected around sample volume and batch size. Its controls include a backlit LCD, and it can store up to nine personal programs.

For an equipment replacement, begin by recording the tubes currently used and how many samples need processing together. This helps distinguish a requirement for more tube positions from a requirement for larger tubes. Select the rotor and any necessary adapters as part of the purchase.


OHAUS FC2706 with R11 rotor: a six-place 50 mL package

 

ohaus-fc2706-with-r11-rotor-6-x-50ml-frontier-2000-multi-centrifuge

The FC2706 with R11 rotor combines the instrument with the OH30694811 angle rotor for six 50 mL tubes.

This package is worth comparing when 50 mL processing is already part of your laboratory’s requirements. Its purchasing advantage is a clearly identified instrument-and-rotor combination. Confirm the dimensions and type of your tubes, any adapter requirements and the operating limits of that configuration before ordering.


OHAUS FC2516: assess against specialist preparation needs

 

ohaus-fc2516-frontier-2000-micro-centrifuge

The OHAUS FC2516 Frontier 2000 Micro Centrifuge is intended for applications including DNA/RNA preparation and ultrafiltration. The instrument listing specifies a maximum relative centrifugal force of 19,080 × g and offers several rotor options.

Include it in your equipment review when existing preparation methods require capabilities beyond a basic mini centrifuge. Match the selected rotor’s performance and capacity to those methods, and confirm what is supplied with the instrument.


Replenish rotors, adapters and sample tubes

 

Replacement accessories can restore an existing setup or extend its usefulness. Count these separately during the stocktake so missing components do not disappear into a general equipment request.

Product Model or size Purchasing purpose
OHAUS 12 × 15 mL angle rotor OH30694907; FC2706 Add a twelve-position 15 mL configuration
OHAUS eight-place microtube rotor OH30129559; FC5306 Replace the rotor for 1.5/2 mL tubes
OHAUS PCR strip rotor OH30129560; FC5306 Replace the four-place PCR strip rotor
OHAUS adapter packs FC5306; eight adapters per pack Replenish the correct 0.2 mL or 0.5 mL adapters
Polypropylene microcentrifuge tubes Packs of 100; 0.5, 1.5 and 2 mL options Replenish sample containers after checking fit and operating rating

 


Choose adapters by tube size

 

Our FC5306 adapters are available as separate eight-packs for 0.2 mL tubes (OH30129561) and 0.5 mL tubes (OH30129562). Record both the size and product code when replacing missing adapters. This makes the order more precise than requesting a generic set of centrifuge accessories.

Restock tubes by the sizes actually used

Our polypropylene microcentrifuge tubes have graduation markings and integrated snap-on caps, with 0.5 mL, 1.5 mL and 2 mL options supplied in packs of 100. Count each size separately when preparing your replenishment order.

Nominal volume alone does not establish suitability for every centrifuge. Confirm tube dimensions, rotor fit and the permitted centrifugal force for the intended use, particularly when purchasing supplies for higher-force equipment.


Frequently asked questions

 

Which OHAUS centrifuge should our laboratory compare first?
Start with the sample format. Review the FC5306 for routine microtube spin-downs, the FC2706 range for larger-volume configurations, and the FC2516 where specialist microtube preparation is an established requirement.

What is the difference between the FC2706 and FC2706+R11?
The standalone FC2706 listing offers rotor options separately. The FC2706+R11 package includes the OH30694811 six-place 50 mL angle rotor.

Does a higher maximum speed make a centrifuge a better purchase?
Maximum speed alone is not enough to select a system. Compare the required centrifugal force, rotor configuration, tube compatibility and samples per run.

Should we replace the whole centrifuge if accessories are missing?
First identify the missing components and check whether compatible replacements are available. A replacement rotor or adapter pack may address the shortage when the instrument remains serviceable and suitable.


Prepare a complete centrifuge order for 2027

 

Make your end-of-year purchasing list specific: identify the instrument, rotor, adapters and sample containers each preparation area needs. This helps direct equipment spending towards complete, usable setups.

Explore the linked OHAUS centrifuges and accessories at Wiltronics to plan replacements, expand suitable existing systems and replenish your prep room before the new school year.


© Electrotech Brands Pty Ltd 2026


Write a Comment

0 Comments